Skip to content
Snippets Groups Projects
  1. Mar 27, 2021
  2. Mar 26, 2021
  3. Mar 25, 2021
  4. Mar 23, 2021
  5. Mar 21, 2021
  6. Mar 20, 2021
    • Deucе's avatar
      Add three new socket status functions: · 99f25324
      Deucе authored
      socket_readable() returns TRUE if recv() will not block if called
      on the specified socket.
      
      socket_writable() returns TRUE if send() will not block if called
      on the specified socket.
      
      socket_recvdone() returns TRUE if all data has been recv()ed an
      the socket is closed.
      
      "will not block" includes "will return an error".
      
      This matches the three main use-cases for select() of a single socket
      in Synchronet.
      
      Use them in the SyncTERM RLogin stuff so they can be tested easily.
      99f25324
    • Deucе's avatar
      Add support for MinGW-w64 · 1dc1a6b9
      Deucе authored
      MinGW32 is getting long in the tooth and is missing a lot of modern
      Windows features as well as having broken headers.  Most people will
      be using MinGW-w64 at this point, so add support for it.  Once I
      ensure SyncTERM works properly with it, MinGW32 support will be
      discontinued.
      
      I suspect this will impact exactly zero people since the reason this
      exists is to build the Win32 versions of SyncTERM on FreeBSD.
      
      Changes:
      - Explicitly request 32-bit Windows output
      - Detect the string "mingw32" anywhere in the hardware description
      - Explicitly link with libuuid
      - Add a terrible hack to syncterm.c to block wincrypt.h
      1dc1a6b9
    • Deucе's avatar
      Ensure cleared block in in scrolling region · 5abc5cda
      Deucе authored
      Do not clear at the current X/Y on scroll (derp)
      5abc5cda
    • Deucе's avatar
      Fix error on scroll with left/right margins · 2f33ee73
      Deucе authored
      Scrolling would clear the line to the end of the screen, not the
      end of the scrolling region.
      
      Sorry echicken.
      2f33ee73
    • Rob Swindell's avatar
      Track the active client "highwater mark" (highest number of concurrent clients) · b881935a
      Rob Swindell authored
      Could be useful for knowing if you need to increase MaxClients for typical
      usage.
      b881935a
    • Rob Swindell's avatar
      Refactor the get_pw() and get_ticpw() methods · 6aade458
      Rob Swindell authored
      First look for a linked node matching the node address string as passed,
      then look for a match using the normalized address (removing .0 and @domain).
      The "ALL" wildcard should not be used for password lookups.
      
      This should fix reported issue 240.
      6aade458
  7. Mar 19, 2021